Mie theory: Test values Parent topic
 
Table 5. Comparison between the S1-function values obtained with the MJC Light Scattering Calculator for Homogeneous Sphere (column HS) and those obtained by Grehan and Gouesbet (1979) with their SUPERMIDI program for the relative particle size, x = 8 and complex refractive index, m, with the real part of m' = 1.33 and various values of the imaginary part, m". At scattering angles of 0° and 180°, one has |S1| = |S2|.
 
  | S1(0°) |2 | S1(180°) |2
m" HS SUPERMIDI HS SUPERMIDI
 0.0001  2939.4  2940  3.791  3.79
 0.01  2764.6  2765  2.385  2.385
 0.1  1856.4  1857  0.2913  0.291
 1  1585.3  1585  2.971  2.97
 10  1344.1  1344.1  16.163  16.163
 100  1120.4  1120.1  14.960  14.96
 1000  1105.95  1106.0  14.941  14.941
 10000  1104.6  1104.6  14.939  14.939


CITATION:
Jonasz M. 2006. Mie theory: Test values (www.tpdsci.com/Tpc/MieTestVal.php). In: Top. Part. Disp. Sci. (www.tpdsci.com).